No manual entry
Values from the device are filed in the patient record without retyping. For devices that send them, the PDF report and histograms are kept with the result.
Cortex runs on your clinic computer. It receives results from hematology, chemistry, blood gas, urine and ultrasound devices, stores them encrypted and delivers them to the patient record in Connect.
Automatic result transfer with Cortex is included in Pro and Max.
See how it works
CBC result received and added to the patient record.
No more reading results off a screen and typing them in. Lab values land in the patient record, X-ray and ultrasound images arrive in Connect, and you open the images in your browser with Vetigen Viewer.

Values from the device are filed in the patient record without retyping. For devices that send them, the PDF report and histograms are kept with the result.
Results without a clear patient and quality-control runs are never added to a patient on their own; they wait for your confirmation in Connect.
Open X-ray and ultrasound images from Connect in Vetigen Viewer to compare and measure them.

We set up Cortex and pair your devices with you. After that, results arrive the same way every day.
Install Cortex on a clinic computer. An authorized user approves the setup link in Connect; there is no key to copy.
Cortex scans for devices on the computer and the clinic network. In Connect, you choose the device model and connection, then point the device’s result output to Cortex.
When the order’s Test ID is entered on the device, the result is linked to the patient record automatically. Unmatched results wait for your confirmation in Connect.
Confirmed lab results appear in the PetConnect app of pet owners who use it, with a notification when they are ready.
Ready-made connection profiles cover more than 40 device models. If your device isn’t listed, we’ll assess compatibility with you.
Results from IDEXX analyzers arrive through VetLab Station and InterLink, which require a Windows computer.
The patient list is sent to the device, and images arrive in the patient record.
If your X-ray, intraoral dental X-ray or ultrasound software saves DICOM images to a folder, Cortex brings them into the Connect inbox and you choose the patient.
Connections: serial port, local network, Wi-Fi, shared folder and HTTPS. Protocols: HL7 v2, ASTM, DICOM and vendor-specific formats.
Cortex keeps results safe on its side until they reach Connect.
Each result is written to an encrypted local queue before the device is told it was received. If the internet drops, delivery retries automatically, and the same result is never recorded twice.
Queued data is encrypted with AES-256-GCM using a key bound to this computer. Requests are signed and sent over TLS 1.3.
Every update is installed only after its signature is verified. If something goes wrong, Cortex rolls back to the previous version on its own.
Runs on macOS, Windows and Linux. You can install Cortex on more than one computer; each device connects to the computer you choose in Connect.
Cortex is installed on a clinic computer. An authorized user approves the setup link in Connect, then you add your devices from Connect. Our team checks device compatibility and supports you during setup. macOS, Windows and Linux are supported.
Ready-made profiles cover more than 40 models from Mindray, Heska, IDEXX VetLab Station, FUJIFILM, Radiometer, Edan, Eaglenos, Bionote, URIT, Diatron, Boule and other manufacturers. Connections use HL7 v2, ASTM, DICOM and vendor-specific formats over a serial port, the local network, a shared folder or HTTPS. If your device isn’t listed, we’ll assess compatibility with you.
When the order’s Test ID is entered on the device, Cortex links the result to that patient’s record. Results without a clear patient, with a species mismatch or from quality-control runs are never added to a patient on their own; they wait for your confirmation in Connect. Manual matches are recorded with a reason.
Cortex writes results to an encrypted local queue and retries delivery automatically when the connection returns. A result counts as delivered once Connect confirms receipt, and the same result is never recorded twice.
Automatic result transfer from supported devices is included in Pro and Max. On Free, you can enter lab results manually or upload PDFs and photos.
When you ask, Veti prepares a structured preliminary review of the results, using your Veti allowance. The clinical decision always stays with the veterinarian.
Yes. Confirmed lab results appear in the PetConnect app of pet owners who use it, with a notification when they are ready.
Device connectivity is one part of the laboratory workflow. For a broader look at how veterinary teams review laboratory reports alongside patient history, explore our guide.
Veterinary laboratory results interpretation guideTell us which devices your clinic uses. We’ll check compatibility and plan the setup with you.
Read the setup guide